Details
Features
- Universal full range AC input
- 3rd generation ultra thin model, high efficiency, compliance to higher safety standards
- No load power consumption <0.5w for 200w below model
- Complete protection function
- Built-in EMI filter, extreme low ripple
- 100% full load burn-in test
- Working temperaure -30℃~+70℃(refer to derating curve)
- Conform to EN60950 GB4943 UL60950 Safety standards
- Conform to GB9254 EN55022 Class B, EMC standards
Industrial control, security, communication, household appliances, LED lighting etc.fields
AC input voltage range | 90~132VAC/170~264VAC 47~63Hz or 240~373VDC |
Over load protection | 110~150% hiccup mode, auto-recovery |
Over-voltage protection | 115~135% cut off the output, restart |
Over-temp protection | TSW1>=100℃±10℃cut off the output, auto-recovery |
Withstand voltage |
I/P-O/P:3KvAC 1 minute I/P-FG:2KvAC 1 minute O/P-FG:0.5KVAC 1 minute |
Working temperature | -30℃~+70℃, 20%~90%RH |
Weight/packing | 0.43kg/30pcs/13.9kg/0.023m³/0.82CUFT |
Model | Output | Error | Range | Efficiency |
LRS-150-5 | 5v, 0-20a | ±3% | 100mV | 84.5% |
LRS-150-12 | 12v, 0-12.5a | ±2% | 120mV | 87% |
LRS-150-24 | 24v, 0-6.5a | ±1% | 150mV | 89% |
View more about LRS-150W on main site