LPV-35E

LPV-35E


Specifications
Details

Features:
‧Constant voltage design
‧Universal AC input / Full range
‧Withstand 300VAC surge input for 5 seconds
‧Protections: Short circuit / Overload / Over voltage
‧Cooling by free air convection
‧Fully encapsulated with IP67 level(Note.9)
‧Fully isolated plastic case
‧Class II power unit, no FG
‧Class 2 power unit
‧Pass LPS
‧Suitable for LED lighting and moving sign applications(Note.8)
‧100% full load burn-in test
‧Low cost, high reliability
‧3 years warranty


Model LPV-35E-5 LPV-35E-12 LPV-35E-15 LPV-35E-24
 
 
Output
DC voltage 5V 12V 15V 24V
Rated current 5A 3A 2.4A 1.5A
Current  range 0~6A(Note.7) 0~3A 0~2.4A 0~1.5A
Rated  power 30W 36W 36W 36W
Ripple&noise (max.) 80mVp-p 120mVp-p 120mVp-p 150MVp-p
Voltage tolerance ±6.0% ±5.0%
Line regulation ±1.0%
Load regulation ±4.0% ±2.0%
Setup,rise time 500ms, 20ms / 230VAC    500ms, 20ms / 115VAC at full load
Hold up time 50ms/230VAC    16ms/115VAC at  full  load
      Input Voltage range 90 ~ 264VAC 127 ~ 370VDC
Frequency range 47 ~ 63Hz
Efficiency 77% 84% 84% 85%
AC current 1.1A/115VAC     0.7A/230VAC
Inrush current Cold start 55A(twidth=510μs measured at 50% Ipeak) at 230VAC
Leakage current 0.25mA/240VAC
 
Protection
Overload 110 ~ 150% rated output power
Protection type:hiccup mode,auto-recovery after fault condition is removed
Over voltage 5.75~ 6.75V 13.8~ 16.2V 17.5~ 20.25V 27.6~32.4V
Protection type : Shut off o/p voltage, clamping by zener diode
Environment WORKING TEMP. -30 ~ +65℃ (Refer to "Derating Curve")
Working humidity 20%~90%RH  non-condensing
Storage temp,humidity -40℃~+80℃,10%~95%RH
Temp. coefficient ±0.03%/℃ (0 ~ 50℃)
Vibration   10~500HZ,2G 10min/1cycle,period for 60min, X.Y.Z each axes
 
Safety&EMC
Safety standard         UL1310, CAN/CSA C22.2 No. 223-M91, IP67 approved ; design refer to TUV EN60950-1
Withstand voltage I/P-O/P:3KVAC
Isolation resistance I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH
EMC emission Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class A, EN61000-3-3
EMC immunity Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
Others MTBF 710Khrs min.      MIL-HDBK-217F (25℃)
Dimension 148*40*30mm (L*W*H)
Packing 0.32Kg; 50pcs/16Kg/0.63CUFT
 
NOTE:
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 ℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minute.
8. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.


View more about LPV-35E on main site